QJ Submersible Deep Well Pump

Product Introduction:

The QJ submersible deep well pump is a water-lifting device that operates by directly connecting the motor with the pump and submerging it into water. It is suitable for extracting underground water from deep wells and can also be used for water lifting projects in rivers, reservoirs, and water channels. Mainly used for irrigation in farmland and mountainous areas, it can also supply water for urban areas, factories, railways, mines, and construction sites.

Product Features:

The motor and pump are integrated and operate submerged in water, ensuring safety and reliability.

There are no special requirements for well pipes and delivery pipes (i.e., steel pipes, ash pipes, and soil wells can be used; steel pipes, rubber pipes, plastic pipes, etc., can be used as delivery pipes under allowable pressure).

Easy to install, use, and maintain, occupies a small area, and does not require the construction of a pump house.

Simple structure, saving raw materials. The suitability of the submersible pump for use is directly related to proper management and its service life.

Conditions of Use:

Rated frequency is 50Hz, and the rated voltage is 380±5% volts for three-phase AC power supply.

The water inlet of the pump must be below 1 meter of the dynamic water level, but the submersible depth must not exceed 70 meters below the static water level, and the lower end of the motor must be at least 1 meter above the bottom of the well.

The water temperature should generally not exceed 20°C.

Water quality requirements: (1) The sand content in water should not exceed 0.01% (by weight). (2) The pH value should be in the range of 6.5 to 8.5. (3) Chloride ion content should not exceed 400 mg/L.

Requirements for well integrity and smooth wall surface.

Structural Description:

The QJ deep well pump consists of a water pump, submersible motor (including cable), delivery pipe, and control switch. The submersible pump is a single-suction multistage vertical centrifugal pump, and the submersible motor is a closed-filled wet-type vertical three-phase cage asynchronous motor. The motor and pump are directly connected through a claw-type or single-gear coupling. Different specifications of three-core cables are provided. The starting equipment includes air switches and self-reducing starters of different capacity levels. The delivery pipe is made of steel pipes of different diameters, connected by flanges, and high-lift pumps are controlled by gate valves.

Each stage guide vane of the submersible pump is equipped with a rubber bearing. The impeller is fixed on the pump shaft with a tapered sleeve, and the guide vanes are threaded or bolted together.

The high-lift submersible pump is equipped with a check valve at the top to prevent unit damage caused by water hammer during shutdown.

The upper part of the submersible motor shaft is equipped with a labyrinth sand-prevention device and two reverse-installed skeleton oil seals to prevent sand from entering the motor.

The submersible motor adopts water-lubricated bearings. The lower part is equipped with a rubber pressure-regulating diaphragm and pressure-regulating spring to form a pressure-regulating chamber, adjusting the pressure changes caused by temperature. The motor winding adopts polyethylene insulation, and the cable adopts durable consumer-grade waterproof electromagnetic wire. The cable connection method follows the QJ cable jointing process, where the insulation of the joint is stripped and scraped clean, securely welded, wrapped with raw rubber, wrapped with 2-3 layers of waterproof adhesive tape, and covered with 2-3 layers of waterproof cloth or bonded with water-based adhesive tape to prevent water leakage.

The motor is sealed with precision stop bolts, and the cable outlet is sealed with a rubber pad.

There is a water injection hole at the upper end of the motor, an air release hole, and a water discharge hole at the lower end.

The lower part of the motor is equipped with upper and lower thrust bearings, with grooves on the upper thrust bearing for cooling, and it is matched with a stainless steel thrust plate that withstands the axial force of the pump.

Serial number Applicable Model Traffic General Yang Cheng Speed Efficiency Motor power Large unit
Small well diameter (model) (cubic meters/hour) (meters) (rev/min) (%) (kilowatt) Outer diameter (mm)
1 150 150QJ(R)5-10O 5 100 2850 60 3 136
2 150OJ(R)5-150 150 4
3 1500J(R)5-200 200 5.5
4 150QJ(R)5-250 250 7.5
5 15OQJ(R)5-300 300 9.2
6 150QJ(R)5-350 350 11
7 15OQJ(R)5-400 400 13
8 150QJ(R)10-50 50 3
9 1500J(R)10-100 100 5.5
10 150QJ(R)10-150 150 7.5
11 150 15OQJ(R)10-200 10 200 2850 64 11 136
12 15OQJ(R)10-250 250 13
13 15OQJ(R)10-300 300 15
14 1500J(R)10-350 350 18.5
15 15OQJ(R)20-26 26 3
16 1500J(R)20-33 33 3
17 15OQJ(R)20-39 39 4
18 15OQJ(R)20-52 52 5.5
19 15OQJ(R)20-72 72 7.5
20 15OQJ(R)20-78 78 7.5
21 150 15OQJ(R)20-85 20 85 2850 65 9.2 136
22 15OQJ(R)20-98 98 9.2
23 15OQJ(R)20-104 104 11
24 15OQJ(R)20-111 111 11
25 15OQJ(R)20-124 124 13
26 15OQJ(R)20-137 137 15
27 150QJ(R)20-143 143 15
28 15OOJ(R)20-156 156 15
29 15OQJ(R)20-176 176 18.5
30 15OQJ(R)20-182 182 18.5
31 15OQJ(R)32-18 18 3
32 15OQJ(R)32-24 24 4
33 15OQJ(R)32-30 30 5.5
34 15OQJ(R)32-36 36 5.5
35 15OQJ(R)32-42 42 7.5
36 150 15OQJ(R)32-54 32 54 2850 66 9.2 136
37 15OQJ(R)32-66 66 11
38 1500J(R)32-72 72 13
39 150QJ(R)32-84 84 13
40 15OOJ(R)32-90 90 15
41 15OQJ(R)32-96 96 15
42 15OQJ(R)32-108 108 18.5
43 200 200QJ(R)20-40 20 40 2850 67 4 136
44 2OOQJ(R)20-54 54 5.5
45 2OOQJ(R)20-81 81 7.5
46 2000J(R)20-93 93 9.2
47 2OOQJ(R)20-108 108 11
48 2OOQJ(R)20-121 121 13
49 2000J(R)20-148 148 15
50 200QJ(R)20-175 175 18.5
 
Serial number Applicable Model Traffic General Yang Cheng Speed Efficiency Motor power Large unit
Small well diameter (model) (cubic meters/hour) (meters) (rev/min) (%) (kilowatt) Outer diameter (mm)
51 200 2OOQJ(R)20-202 20 202 2850 67 22 184
52 200QJ(R)20-243 243 25
53 200QJ(R)20-270 270 30
54 2OOQJ(R)20-297 297 30
55 200QJ(R)20-351 351 37
56 2000J(R)20-391 391 45
57 2000J(R)32-26 26 4
58 2000J(R)32-39 39 5.5
59 2000J(R)32-52 52 7.5
60 2000J(R)32-65 65 9.2
61 200 2000J(R)32-78 32 78 2850 70 11 184
62 2000J(R)32-91 91 13
63 2OOQJ(R)32-104 104 15
64 2000J(R)32-130 130 18.5
65 200QJ(R)32-143 143 22
66 2OOQJ(R)32-156 156 25
67 2OOQJ(R)32-169 169 25
68 2OOQJ(R)32-195 195 30
69 2OOQJ(R)32-234 234 37
70 2OOQJ(R)32-247 247 37
71 200 2000J(R)32-299 50 299 2850 74 45 184
72 2000J(R)50-26 26 5.5
73 200QJ(R)50-39 39 9.2
74 2000J(R)50-52 52 11
75 2OOQJ(R)50-65 65 15
76 200QJ(R)50-78 78 18.5
77 200QJ(R)50-91 91 22
78 2000J(R)50-104 104 25
79 2000J(R)50-130 130 30
80 200QJ(R)50-156 156 37
81 2OOQJ(R)50-182 182 45
82 2000J(R)80-22 22 7.5
83 2OOQJ(R)80-33 33 11
84 2OOQJ(R)80-44 44 15
85 200QJ(R)80-55 55 18.5
86 200 2OOQJ(R)80-66 80 66 2850 75 22 184
87 200QJ(R)80-77 77 30
88 200QJ(R)80-88 88 30
89 2000J(R)80-99 99 37
90 2OOQJ(R)80-121 121 45
91 250 250QJ(R)50-20 50 20 2875 73 5.5 233
92 25OQJ(R)50-40 40 9.2
93 250QJ(R)50-60 60 13
94 25OQJ(R)50-80 80 18.5
95 2500J(R)50-100 100 22
96 2500J(R)50-120 120 25
97 2500J(R)50-140 140 30
98 25OQJ(R)50-160 160 37
99 250QJ(R)50-200 200 45
100 2500J(R)50-240 240 55
 
Serial number Applicable Model Traffic General Yang Cheng Speed Efficiency Motor power Large unit
Small well diameter (model) (cubic meters/hour) (meters) (rev/min) (%) (kilowatt) Outer diameter (mm)
101 250 250QJ(R)50-280 50 280 2875 73 63 233
102 250QJ(R)50-320 320 75
103 250QJ(R)50-360 360 90
104 250QJ(R)50-400 400 90
105 250QJ(R)50-440 440 100
106 250QJ(R)50-480 480 110
107 250QJ(R)80-20 20 7.5
108 250QJ(R)80-40 40 15
109 250QJ(R)80-60 60 22
110 250QJ(R)80-80 80 30
111 250 250QJ(R)80-100 80 100 2875 75 37 233
112 250QJ(R)80-120 120 45
113 250QJ(R)80-140 140 55
114 250QJ(R)80-160 160 55
115 250QJ(R)80-180 180 63
116 250QJ(R)80-200 200 75
117 250QJ(R)80-240 240 90
118 250QJ(R)80-280 280 100
119 250QJ(R)80-320 320 110
120 25OQJ(R)100-18 18 7.5
121 250 25OQJ(R)100-36 100 36 2875 75 15 233
122 25OQJ(R)100-54 54 25
123 250QJ(R)100-72 72 30
124 25OQJ(R)100-90 90 37
125 250QJ(R)100-108 108 45
126 25OQJ(R)100-126 126 55
127 250QJ(R)100-144 144 63
128 25OQJ(R)100-162 162 75
129 250QJ(R100-180 180 75
130 250QJ(R)100-198 198 90
131 25OQJ(R)100-216 216 100
132 250QJ(R)100-252 252 110
133 25OQJ(R)125-16 16 9.2
134 250QJ(R)125-32 32 18.5
135 250QJ(R)125-48 48 25
136 250 250QJ(R)125-64 125 64 2875 76 37 233
137 25OQJ(R)125-80 80 45
138 250QJ(R)125-96 96 55
139 250QJ(R)125-112 112 63
140 25OQJ(R)125-128 128 75
141 250QJ(R)125-160 160 90
142 25OQJ(R)125-176 176 100
143 25OQJ(R)125-196 196 110
144 250QJ(R)125-352 352 180
145 250QJ(R)140-15 15 9.2
146 250 250QJ(R)140-30 140 30 2875 76 18.5 233
147 250QJ(R)140-45 45 30
148 25OQJ(R)140-60 60 37
149 25OQJ(R)140-75 75 45
150 250QJ(R)140-90 90 55
 
Serial number Applicable Model Traffic General Yang Cheng Speed Efficiency Motor power Large unit
Small well diameter (model) (cubic meters/hour) (meters) (rev/min) (%) (kilowatt) Outer diameter (mm)
151 250 250QJ(R)140-105 140 105 2875 76 63 233
152 250QJ(R)140-120 120 75
153 250QJ(R)140-150 150 90
154 250QJ(R)140-165 165 100
155 250QJ(R)140-180 180 110
156 250QJ170(R)-20 20 15
157 250QJ170(R)-40 40 30
158 250QJ170(R)-60 60 45
159 250 250QJ170(R)-80 170 80 2900 75 63 233
160 250QJ170(R)-10 100 75
161 250QJ170(R)-120 120 90
162 250QJ170(R)-140 140 110
163 250QJ(R)200-20 20 18.5
164 250QJ(R)200-40 40 37
165 250QJ(R)200-60 60 55
166 250 25OQJ(R)200-80 200 80 2875 70 75 233
167 250QJ(R)200-100 100 90
168 25OQJ(R)200-120 120 110
169 250QJ(R)200-200 200 180
170 300 300QJ(R)200-20 200 20 2900 76 18.5 281
171 3OOQJ(R)200-40 40 37
172 3OOQJ(R)200-60 60 55
173 3OOQJ(R)200-80 80 75
174 300QJ(R)200-160 100 90
175 300QJ(R)200-120 120 100
176 3OOQJ(R)200-140 140 125
177 3OOQJ(R)200-160 160 140
178 300QJ(R)200-180 180 160
179 3OOQJ(R)200-200 200 185
180 300QJ(R)200-240 240 220
181 300QJ(R)300-22 22 30
182 3OOQJ(R)300-44 44 55
183 3OOQJ(R)300-66 66 90
184 300 300QJ(R)300-88 300 88 2900 70 125 281
185 300QJ(R)300-110 110 160
186 300QJ(R)300-132 132 185
187 300QJ(R)300-154 154 220
188 350 3500J200(R)-36 200 36 1450 75 30 328
189 350QJ200(R)-48 48 45
190 350QJ200(R)-60 60 55
191 350QJ200(R)-72 72 63
192 350QJ200(R)-84 84 75
193 3500J200(R)-96 96 90
194 3500J200(R)-120 120 110
195 3500J200(R)-144 144 125
196 350QJ200(R)-168 168 140
197 350QJ200(R)-192 192 160
198 3500J(R)360-36 36 55
199 350 350QJ(R)360-72 360 72 2900 76 125 330
200 3500J(R)360-108 108 160

* Subject